Current Doubler
Topology: Myth and Reality.
To our knowledge, this is the
first article (and the only one to date), to realistically
compare the Center Tap topology with the Current Doubler
equivalent, using waveforms and numbers, and not "feelings"
and "qualitative" explanation of what is happening. In
this article the reader will find actual calculations and
simulation waveforms of main parameters.
It is unfortunate that far too
many technical articles are concentrating on an extremely narrow
aspect of a particular problem, ignoring that the problem is part
of a much wider picture. It is true, that in order to analyze a
phenomenon, an engineer, a scientist, a doctor must break a
problem in smaller pieces, being easier to handle and analyze.
But ignoring the bigger picture is misleading the reader.
There are several articles out
there regarding the "Current Doubler" topology and
describing the advantages of using it. But none of them (or at
least none of those published in reputable magazines,
proceedings, or by well known designers) are telling the whole
story. This article is an attempt to give readers a much more
accurate image of what actually happens when you decide to use a
"Current Doubler" topology instead of a "Center
Tap".
We will consider, for our
analysis, the DC/DC section of the following switch mode power
supply:
- Vin=407Vdc
- Vout=27.22Vdc
- Iout=90A
- (Pout=2.5kW)
- fsw=200kHz (we will use as
a definition of the switching frequency, the frequency
"seen" by the power/isolation transformer)
- Duty Cycle=0.793
Three options will be considered:
- "Center Tap"
- "Current Doubler",
with the output inductors value chosen to preserve the
same primary currents as "Center Tap"
- "Current Doubler 2",
with the output inductors value chosen twice the value
used in the "Center Tap"
Following is a table summarizing
the results. You can see also the corresponding waveforms or
calculated values, by clicking on the highlighted parameter.
And now the comments:
Myth: " ... operation on
the primary side, including duty-cycle is unchanged ... diode and
output capacitor stresses are identical to full-wave technique
... "
Reality:
- Identical operation on the
primary side and identical stress on IDENTICAL output
capacitors can not be achieved simultaneously. From the
table and waveforms shown above it becomes clear that you
have two major options (among many other), that you can
choose from.
- One major option would be
to preserve, relative to the "Center Tap", same
operation in the primary side (peak and RMS primary
current). By doing that, you need the output inductors to
have, each of them, an inductance 11 times higher
than the "Center Tap" design! You have a
benefit by doing this, the output capacitor can have 5
time lower capacitance than the "Center Tap",
for the same OUTPUT VOLTAGE RIPPLE.
- Second option would be to
preserve SAME OUTPUT VOLTAGE RIPPLE, using SAME
OUTPUT CAPACITANCE as the "Center Tap".
This would allow you to use a value for the output
inductors twice the value used in the Center Tap
topology, value that is suggested in most articles
describing the Current Doubler topology. However, this
approach will change drastically the current shape in the
primary of the power transformer. In our example, the
peak current changed by almost 50%. Someone may argue
that this is not that bad. This is absolutely true, and
actually may be beneficial in achieving soft switching.
However, this kind of reasoning logically is
fundamentally flawed, as one would not compare apple with
apple. If you decide that a higher peak current in the
primary side is acceptable (or desirable), you should go
back and analyze also a center tap topology with a higher
ripple current. Therefore, we consider a MUST to compare
Center Tap topology with the equivalent Current Doubler
having the SAME primary currents, otherwise we would
compare apple with pears and not apple with apple.
Myth: " ... the current
doubler working under same conditions as a full wave rectifier
will reduce the copper loss in the transformer secondary by
approximately 50% ... "
Reality:
- First, the 50% claim is for
secondary copper loss, not for total transformer loss. In
our example, if you maintained same currents in the
primary, the secondary copper loss decreased by
approximately 35%. If you considered using the output
inductors twice the value of the center tap
configuration, the secondary loss decreased only by 26%,
while the primary loss INCREASED by 14%! This is because,
not preserving same input current waveshape, the rms
value of the primary and secondary will increase.
- Second, the TOTAL MAGNETICS
LOSSES may increase when you change the output stage
topology from center tap to current doubler! In our
example, the total magnetics losses increased by 27%, or
31.6% if you have not used the correct current doubler
equivalent circuit.
- In our personal opinion,
the secondary copper loss can realistically be reduced by
approximately 35%, if you are using an "optimum
design", using methodologies like the ones described
in papers written by Dowell, Jongsma, Carsten, etc. This
reduced secondary copper loss would result in a typical
reduction of the total power transformer loss of 25%.
This could mean A LOT, or NOTHING, depending of the
application!!!
Other Considerations:
- First of all, we compared
the two topologies using an example, because it is easier
to see the advantages and disadvantages compared with a
theoretical approach. We did not develop specific
generalized formulae to compare the topologies. However,
do not be mistaken to believe that we reached the above
conclusions based on a particular example. Similar
results were obtained for power supplies ranging in power
from 500W to 10kW, and output voltages of 3.3V, 5V, 12V,
24/27V, 48/54V.
- I found in one article the
following statement: "... the current doubler
output stage needs twice the number of turns on the
secondary side 'then its full wave counter part, but only
one winding is needed ...". Let's don't play with words. A current
doubler power transformer has the SAME total number of
turns on the secondary as its center tap equivalent.
- Core loss, in the output
inductors incorrectly scaled to twice the value for the
center tap, is much higher and may require only ferrite
material to be used.
- If you correctly design the
current doubler topology to preserve the same currents in
the primary side, you end up with a much higher output
inductor compared with the center tap. However, the
required output capacitance, for the same output voltage
ripple, will be significantly lower. The result is that
the total energy stored in the output stage is
significantly lower, because, usually, most of
the energy is stored in output capacitors and not in the
output inductor(s).
- The voltage loop of the
output stage is different in center tap then in current
double, and the compensation network has to be changed.
- For the current doubler
topology to work properly, the currents in the two output
inductors have to be balanced. In order to have them
balanced, you can not use voltage mode control or average
current mode control for the output stage. You MUST use
peak current mode control or a similar control method to
force equal average currents in the two output inductors.
- Some of the current doubler
advantages: lower loss in the power transformer, simpler
mechanical structure for the output transformer, lower
output capacitance required for the same voltage ripple.
- When the current doubler
should be consider as an alternative to center tap:
output currents over 100A for fan cooled, over 25A for
natural convection cooled. For currents below 100A in fan
cooled units or below 25A for natural convection cooled
units, we consider that the center tap topology is still
a better alternative.
- Do not rush to conclusions
such as which topology is better after just reading
technical articles. Use your own judgment, for your
particular application, considering: maintaining same
currents in the primary side, calculating ALL
losses in ALL the magnetics components,
calculating ALL costs (parts and labor),
etc.
Current Doubler topology,
prior art:
- 1930 - 1940 ? Topology used
with vacuum tubes.
- 1987 July
22, Denmark patent DK1987000003826, Ole S. Seiersen.
- 1988 July 21, US patent
filed, Ole S. Seiersen.
- 1990 Feb 6,
US patent 4,899,271, Ole S. Seiersen.
- 1991 Jun, HFPC Proceedings,
"A New Efficient High Frequency Rectifier Circuit"
by C. Peng, M. Hannigan and O. Seiersen. Topology name: "Hybridge".
- 1991 Jun, HFPC Proceedings,
"A New Output Rectifier Configuration Optimized For
High Frequency Operation" by Kevan O'Meara. The
topology is not explicitly named "Current Doubler
topology", but it is emphasized the "... output
current doubling property ...".
- 1994 Dec, Unitrode Design
Note DN-63, "The Current-Doubler Rectifier: An
Alternative Rectification Technique For Push-Pull And
Bridge Converters", by Laszlo Balogh.
- SMPS
Intellectual Property
- This article contains information for
which SMPS Power Supplies and its partners may claim
Copyright and/or Trademark rights and may be subject of a
Patent application. Also SMPS Power Supplies and its
partners may claim the status of "First to be
published", relative to ideas published in this
article. Reasonable parts of this article may be quoted
by any third parties, without contacting us, assuming
that the source is clearly identified and a link to the
full article is included. If you wish to incorporate
information from this article within a commercial
product, you should contact us for permission.
- First Revision: 14 Feb
1998
- Web first published: 17
Feb 2000
- Last Revision: 8 Aug 2001
Comments and suggestions are
welcomed and encouraged!
HOME
- Copyright © 1998-2001 SMPS Power
Supplies, Inc. All
rights reserved.
Other brand, product names and
words may be trademarks or registered trademarks of the
respective companies. If considered necessary, a company whose
name/trademark is mentioned in this article may contact us by e-mail,
and we will add a special trademark/copyright notice, linking the
company name with the words in question.